| Air-Cooled Generator |
|
Sixty-six percent (66%) increase in P-3
generator output (from 60 kVA to 100 kVA) by
innovative stator and rotor cooling and
improved electromagnetic design.
|
|
|
|
| Parameter |
|
Existing |
|
IPS |
|
| Envelope |
|
16 in x 9.5 in |
|
16 in x 9.5 in |
|
| Weight |
|
108 lbs |
|
105 lbs |
|
| Overhung Moment |
|
730 in-lb |
|
536 in-lb |
|
| Output |
|
120/208 Vac, 3 phase wye |
|
120/208 Vac, 3 phase wye |
|
| Load |
|
60 kVA |
|
100 kVA |
|
| Overload |
|
90 kVA, 5 minutes |
|
112.5 kVA, 5 minutes |
|
| |
|
120 kVA, 5 minutes |
|
150 kVA, 5 minutes |
|
| Waverform Quality |
|
MS90325 |
|
MS90325 |
|
| Environmental |
|
MIL-E-81910 |
|
MIL-E-81910 |
|
| EMI Specification |
|
MIL-E-81910 |
|
MIL-E-81910 |
|
|
| |
| Oil-Cooled Generator |
|
Fifty-four percent (54%) increase in M-1 tank
generator power output (from 650 Amps to
1000 Amps) while retaining the same envelope
accomplished by using a patented rotor cooling
scheme (patent number US 6,661,133 B2).
|
|
|
|
|
| Parameter |
|
Existing |
|
IPS |
|
| Envelope |
|
16 in x 8 in |
|
16 in x 8 in |
|
| Weight |
|
100 lbs |
|
108.9 lbs |
|
| Overhung Moment |
|
660 in-lb |
|
750 in-lb |
|
| Output |
|
28 Vdc |
|
28 Vdc |
|
| Load |
|
18.2 kW |
|
28 kW |
|
|
| |
| Lower operating temperature significantly increases generator reliability. |